NETWORK INCIDENTS

Every Clock Agreed on 2006: Replaying Telstra's NTP Outage in a Lab

Network+ 3.4 Time protocols: NTPNetwork+ 3.1 Change management and configuration management

On the 8th of July 2026, a wrong date spread through the timing system of Telstra's mobile core network. Some users couldn't make or receive calls, including emergency calls, send or receive messages, or use mobile data. This lab isn't Telstra's network. It rebuilds the failure pattern described in the external review Telstra commissioned, so we can watch it happen.

One time network. nmi is the national time reference; syd2 and mel2 take their time from it (stratum 2); syd3, mel3 and perth3 serve the next level (stratum 3), and mme, a core node, takes its time from those three. mel3 also has its own reference, a GPS card. Every node runs chrony with -x, so it never changes your computer's clock: a wrong date only lives in chrony's own estimate.

Incident replay: a lab model of the failure pattern in the external review of Telstra's 8 July 2026 outage (https://www.telstra.com.au/content/dam/tcom/dynamic-media-projects/luke-campbell/TAP-Findings-for-Telstra-Outage.pdf), not Telstra's network.

The symptom. On mme, chronyc tracking says its reference time is in November 2006.

The lab

The lab is a time hierarchy, and the arrows show where each server takes its time from. nmi is the national reference, at stratum 1, the most trusted level. syd2 and mel2 take their time from it, at stratum 2. perth3 takes its time from both of them, and syd3 only from mel2. mel3 is different: its reference is a GPS card, and it peers with syd3, which means either one can take time from the other. mme is a core node, and it asks all three stratum 3 servers. Every server here runs chrony, set so it never changes the machine's real clock: the wrong date lives only in what each one believes, and passes on.

The symptom

on mme
chronyc tracking
Reference ID    : 0A002820 (mel3)
Stratum         : 2
Ref time (UTC)  : Wed Nov 22 14:41:06 2006
System time     : 630028800.000000000 seconds fast of NTP time
Last offset     : -0.000002199 seconds
RMS offset      : 189008640.000000000 seconds
Frequency       : 0.007 ppm slow
Residual freq   : -0.000 ppm
Skew            : 0.072 ppm
Root delay      : 0.000008702 seconds
Root dispersion : 0.000001988 seconds
Update interval : 0.6 seconds
Leap status     : Normal
What this shows

Start where the damage shows: mme. chronyc tracking shows what chrony believes about the time. Ref time, when it last heard from its source: Wednesday the 22nd of November, 2006. And it believes its own clock is 630 million seconds fast: about twenty years. mme hasn't lost track of the time. It's sure of the wrong one.

Who says so

on mme
chronyc sources
MS Name/IP address         Stratum Poll Reach LastRx Last sample
===============================================================================
^+ syd3                          2   0   377     0  +8171ns[+8171ns] +/-   30us
^* mel3                          1   0   377     2  +1415ns[+1513ns] +/- 6825ns
^x perth3                        3   0   377     0   -7292d[ -7292d] +/-   53us
What this shows

Who told it that? chronyc sources lists the servers it asks. mel3, at stratum 1, has the star: that's the one it's following. syd3 agrees with it, and the plus means it's used alongside. perth3 is 7292 days behind them, and marked x: a falseticker. But perth3 is the one with the right date. Two sources agree and one doesn't, so the majority wins.

on syd3
chronyc sources
MS Name/IP address         Stratum Poll Reach LastRx Last sample
===============================================================================
^? mel2                          2   1     0    25   -7292d[+6780ns] +/-   30us
=* mel3                          1   0   377     0  +1311ns[+1319ns] +/- 6715ns
What this shows

So why do two servers agree on 2006? Ask syd3. Its only stratum 2 source, mel2, has a question mark and a reach of zero: nothing is coming back from it. In the lab we turned mel2 off, as the same chassis replacement did to Melbourne's stratum 2 server. What's left is mel3. The equals sign means a peer, and the star means syd3 is following it. So syd3 isn't a second opinion. It's repeating mel3.

The source

on mel3
chronyc tracking
Reference ID    : 7F7F0101 ()
Stratum         : 1
Ref time (UTC)  : Wed Nov 22 14:40:49 2006
System time     : 630028800.000000000 seconds fast of NTP time
Last offset     : +630028800.000000000 seconds
RMS offset      : 630028800.000000000 seconds
Frequency       : 0.000 ppm slow
Residual freq   : +0.000 ppm
Skew            : 0.000 ppm
Root delay      : 0.000000000 seconds
Root dispersion : 0.000000000 seconds
Update interval : 0.0 seconds
Leap status     : Normal
What this shows

So, mel3. Reference ID 7F7F0101 is chrony's code for a local reference: here, the GPS card. Stratum 1. And the GPS says November 2006. Telstra's GPS card was missing a firmware update for a known GPS rollover. When the chassis came back after a planned change, the card reset and worked out a date 1024 weeks in the past: November 2006. The lab's GPS card was set to that same date.

The fix

on mel3
chronyc add server nmi iburst minpoll 0 maxpoll 1
200 OK
What this shows

The fix in the lab: stop trusting the GPS card. chronyc add server gives mel3 the national reference, nmi, as a source. iburst asks several times quickly at the start, and minpoll and maxpoll make it check every second or two, which only matters in a lab. 200 OK: chrony took it.

Verifying

on mme
chronyc tracking
Reference ID    : 0A002820 (mel3)
Stratum         : 3
Ref time (UTC)  : Mon Nov 09 14:41:31 2026
System time     : 0.000013083 seconds fast of NTP time
Last offset     : +0.000000104 seconds
RMS offset      : 226058368.000000000 seconds
Frequency       : 0.008 ppm slow
Residual freq   : +0.057 ppm
Skew            : 0.028 ppm
Root delay      : 0.000028646 seconds
Root dispersion : 0.000017688 seconds
Update interval : 1.0 seconds
Leap status     : Normal
What this shows

Back on mme. 2026 again. And its clock is a few microseconds off, not twenty years.

on mme
chronyc sources
MS Name/IP address         Stratum Poll Reach LastRx Last sample
===============================================================================
^~ syd3                          3   0   377     1  +4784ns[+4784ns] +/-   51us
^* mel3                          2   0   377     1   +554ns[ +323ns] +/-   30us
^+ perth3                        3   1   377     1  -1340ns[-1340ns] +/-   53us
What this shows

perth3 is back in use, with a plus. syd3 has a tilde: its time is still settling after the jump, so mme leaves it out for now.

Why everyone agreed

Why did the whole network agree on 2006? A time client goes with what most of its sources agree on. Two of mme's three sources traced back to the same bad clock: syd3 was only repeating mel3. So the wrong date had the majority. Telstra's review describes the same shape. After a 2020 change to peering, and a GPS card added as a fix in October 2025, the date spread through a timing loop until the available time sources agreed it was 2006, and the clients accepted it. Not all nodes and applications were affected.

Two independent sources

Give every time server at least two truly independent sources, and keep the hierarchy written down. And after any change to a time server, check it's serving the right time. Telstra's review found nobody did, after the chassis change.

Try it yourself

The whole lab runs on your own computer with Docker and containerlab: get it on GitHub, then ./lab.sh up and ./lab.sh break. Setup steps are on Run the labs.